A patient presented with an irreducible open dorsal dislocation of the distal interphalangeal joint of the index finger. The volar plate was found to be interposed within the joint, and the FDP tendon was wrapped around the radial condyle of the middle phalanx. The joint was reduced and stabilized with a longitudinal Kirschner -wire, resulting in a good functional outcome for the patient.
Authors: Ciara A. Brown MD, Paul A. Ghareeb MD
Subspecialty: Hand/Peripheral Nerve
Disclaimer: The content and CPT codes included in this case report are accurate up to and on the publication date. Please note that CPT codes may change; and the ones included are specific to this case at the time of publication. It is recommended that you check with the appropriate coding resources for the most current codes and application.